Method of application Usage Instructions
I. Deep throat sputum (preferred method)
1. Best conducted first thing in the morning before rinsing your mouth or brushing your teeth
2. Unscrew the purple top from the dropper tube, cut or twist snap open the diluent vial and add 10 drops of solution into the dropper tube
3. Inhale deeply and exhale forcefully, repeat three times
4. Cough deep from within your chest to produce sputum
5. Spit your sputum (slight yellow/green colour) into the sputum dish
6. Use the sterile swab stick to mix and cover it fully with the sputum
……Continue to [Conducting the test]


II. Throat & Tonsil swab method (alternative method)
1. The swabbing procedure should be conducted by a second person
2. Unscrew the purple top from the dropper tube, cut or twist snap open the diluent vial and add 10 drops of solution into the dropper tube
3. Remove the sterile swab stick from the wrapper being careful to avoid contacting the tip with any foreign surface
4. Instruct the person being tested to open his mouth and say “ahhh”. When swabbing children, it is advisable to depress their tongue with the back of a teaspoon for ease of application and additional safety
5. Swab the back of the throat including the left and right tonsil area, taking care not to contact the swab tip with any other part of the mouth
………Continue to [Conducting the test]

Conducting the test
1. Insert the swab stick into the dropper tube and rinse it in the solution for 30 seconds
2. Remove the swab stick and dispose safely in the provided plastic bag
3. Replace the purple screw top onto the dropper tube and shake vigorously for approximately 5 seconds
4. Remove the white screw cap from the tip of the dropper tube
5. Add 5 drops of sample into the test cassette well ""S""
6. Wait 15 to 20 minutes
7. Read and record your result
8. Dispose all materials in the plastic bag provided and wash your hands thoroughly

Interpretating the test result
1. Negative Result: quality control mark “C” displays a red band, and testing mark “T” is blank
2. Positive Result: quality control mark “C” and testing mark “T” both display red bands
3. Invalid Result: quality control mark “C” is blank, regardless testing mark “T” status

Please refer to the Instruction Manual.

Way of storage
The product should be stored in a cool place. The product is stable until the expiration date indicated on the outer package.

Country of origin
Singapore